The Test Transformer(ac dc hipot tester) calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage.
AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance, and light weight.
3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive.
4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install.
warning
1. Test transformer should be applied into use with control unit as for how to use control unit please see Operation Manual of Control unit.
2. Screening wire should be applied into the direct current test to avoid straying leakage. After test discharge rod is applied to release the restored electricity.
3. The end of high frequency voltage filtering capacitance should be connected with the ground wire together with crust of control unit to connect with the earth wire.
4. The whole test should follow the regulation in high frequency voltage test site should pay more attention to the safety of equipment and body.
voltage classes | 10kV~300kV |
range of capacity | 1~500kVA |
no-load current | <7% |
impedance voltage | <8% |
product classification | interflow,ac/dc,Ac cascade,Ac-dc cascade |
specifications and models | capacity(kVA) | High Voltage(kV) | High tension current(mA) | low input voltage converter | bend-beam-rheometer | temperature rise℃(30 minutes) | |
voltage(V) | electricity(A) | ||||||
YDQ-1.5/50 | 1.5 | 50 | 30 | 200 | 7.5 | 500 | 10 |
YDQ-3/50 | 3 | 50 | 60 | 200 | 15 | 500 | 10 |
YDQ-5/50 | 5 | 50 | 100 | 200 | 25 | 500 | 10 |
YDQ-10/50 | 10 | 50 | 200 | 200 | 50 | 500 | 10 |
YDQ-20/50 | 20 | 50 | 400 | 400 | 53 | 500 | 10 |
YDQ-30/50 | 30 | 50 | 600 | 400 | 79 | 500 | 10 |
YDQ-50/50 | 50 | 50 | 1000 | 400 | 12 | 500 | 10 |
YDQ-5/100 | 5 | 100 | 50 | 200 | 25 | 1000 | 10 |
YDQ-10/100 | 10 | 100 | 100 | 200 | 50 | 1000 | 10 |
YDQ-20/100 | 20 | 100 | 200 | 400 | 53 | 1000 | 10 |
YDQ-30/100 | 30 | 100 | 300 | 400 | 79 | 1000 | 10 |
YDQ-50/100 | 50 | 100 | 500 | 400 | 132 | 1000 | 10 |
YDQ-20/150 | 20 | 150 | 133 | 400 | 53 | 1500 | 10 |
YDQ-30/150 | 30 | 150 | 200 | 400 | 80 | 1500 | 10 |
YDQ-50/150 | 50 | 150 | 333 | 400 | 132 | 1500 | 10 |
YDQ-100/150 | 100 | 150 | 667 | 400 | 263 | 1500 | 10 |
YDQ-50/200 | 50 | 200 | 250 | 400 | 132 | 2000 | 10 |
YDQ-100/200 | 100 | 200 | 500 | 400 | 263 | 2000 | 10 |
YDQ-150/200 | 150 | 200 | 750 | 400 | 395 | 2000 | 10 |
YDQ-200/200 | 200 | 200 | 1000 | 400 | 526 | 2000 | 10 |
YDQ-300/200 | 300 | 200 | 1500 | 400 | 790 | 2000 | 10 |
YDQ-50/300 | 50 | 300 | 170 | 400 | 132 | 3000 | 10 |
YDQ-100/300 | 100 | 300 | 333 | 400 | 263 | 3000 | 10 |
YDQ-150/300 | 150 | 300 | 500 | 400 | 395 | 3000 | 10 |
YDQ-200/300 | 200 | 300 | 667 | 400 | 526 | 3000 | 10 |
YDQ-300/300 | 300 | 300 | 1000 | 400 | 790 | 3000 | 10 |
1,The inflatable test transformer is small in size,in light weight(It is 40%-65 lighter than the same grade oil-immersed transformer)
2,spotless,greaseless,There is no need to maintain
3,Free from adverse weather and environment,The field transport should be stationary and can be tested
4,The insulation strength is obviously higher than that of oil-immersed transformer,Minimal corona